[{"data":1,"prerenderedAt":123},["ShallowReactive",2],{"Kf4LtCQ0h2helUNGPtOwvE01a8k41NxdjJGUAz0BEhc":3,"_apollo:default":121,"_apollo:identified":122},{"seo":4,"posts":15},{"social":5,"openGraph":11,"__typename":14},{"twitter":6,"__typename":10},{"cardType":7,"username":8,"__typename":9},"summary_large_image","dassault3ds","SEOSocialTwitter","SEOSocial",{"defaultImage":12,"__typename":13},null,"SEOOpenGraph","SEOConfig",{"nodes":16,"__typename":120},[17],{"id":18,"slug":19,"title":20,"uri":21,"excerpt":22,"locale":23,"featuredImage":26,"tableOfContents":34,"content":41,"date":42,"translations":43,"author":44,"tags":57,"globalTags":79,"brands":91,"keywords":102,"seo":108,"__typename":119},"cG9zdDozMTcwNjQ=","terminal-strip-design-catia-electrical","Terminal strips: the critical link between schematic and field","\u002Fbrands\u002Fcatia\u002Fterminal-strip-design-catia-electrical","\u003Cp>The terminal strip is where engineering meets assembly. Discover how CATIA Electrical generates it from the schematic and how distributed terminals keep complex strips readable.\u003C\u002Fp>\n",{"locale":24,"__typename":25},"en_US","Locale",{"node":27,"__typename":33},{"large":28,"__typename":29,"medium_large":28,"thumbnail":30,"srcSet":31,"sizes":32},"https:\u002F\u002Fblog-assets.3ds.com\u002Fuploads\u002F2026\u002F10\u002Fterminal-768x419.jpg","MediaItem","https:\u002F\u002Fblog-assets.3ds.com\u002Fuploads\u002F2026\u002F10\u002Fterminal-150x150.jpg","https:\u002F\u002Fblog-assets.3ds.com\u002Fuploads\u002F2026\u002F10\u002Fterminal-300x164.jpg 300w, https:\u002F\u002Fblog-assets.3ds.com\u002Fuploads\u002F2026\u002F10\u002Fterminal-1024x559.jpg 1024w, https:\u002F\u002Fblog-assets.3ds.com\u002Fuploads\u002F2026\u002F10\u002Fterminal-768x419.jpg 768w, https:\u002F\u002Fblog-assets.3ds.com\u002Fuploads\u002F2026\u002F10\u002Fterminal.jpg 1408w","(max-width: 300px) 100vw, 300px","NodeWithFeaturedImageToMediaItemConnectionEdge",[35,36,37,38,39,40],"Managed from the schematic, not redrawn by hand|managed-from-the-schematic-not-redrawn-by-hand-0","Distributed terminals: complexity without the clutter|distributed-terminals-complexity-without-the-clutter-1"," |-2","Why it matters, panel by panel|why-it-matters-panel-by-panel-3","Conclusion|conclusion-4","FAQ|faq-5","\n\u003Cp>The terminal strip is where the cabinet meets the outside world. Every internal wire and every field connection passes through it, which makes it one of the most consulted parts of a project, and one of the least forgiving. An unclear or inconsistent strip does not stay a design problem: it becomes a wiring error on the shop floor, or a lost hour of troubleshooting on site, months after the panel shipped.\u003C\u002Fp>\n\n\n\n\u003Cfigure class=\"wp-block-image size-full\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"945\" height=\"617\" src=\"https:\u002F\u002Fblog-assets.3ds.com\u002Fuploads\u002F2026\u002F10\u002Fimage-6.png\" alt=\"\" class=\"wp-image-317065\" srcset=\"https:\u002F\u002Fblog-assets.3ds.com\u002Fuploads\u002F2026\u002F10\u002Fimage-6.png 945w, https:\u002F\u002Fblog-assets.3ds.com\u002Fuploads\u002F2026\u002F10\u002Fimage-6-300x196.png 300w, https:\u002F\u002Fblog-assets.3ds.com\u002Fuploads\u002F2026\u002F10\u002Fimage-6-768x501.png 768w\" sizes=\"auto, (max-width: 945px) 100vw, 945px\" \u002F>\u003C\u002Ffigure>\n\n\n\n\u003Ch2 class=\"wp-block-heading\" id=\"managed-from-the-schematic-not-redrawn-by-hand-0\">\u003Cstrong>Managed from the schematic, not redrawn by hand\u003C\u002Fstrong>\u003C\u002Fh2>\n\n\n\n\u003Cp>In \u003Cstrong>\u003Ca href=\"https:\u002F\u002Fwww.3ds.com\u002Fproducts\u002Fcatia\u002Felectrical-fluid-engineering\u002Felectrical-engineering?_gl=1*wkfgwa*_gcl_au*NzE3ODg1MTU3LjE3OTExOTI3MTM.*_ga*MTI1MDA2OTQzOS4xNzkxMjc5ODc1*_ga_DYJDKXYEZ4*czE3OTQyMTgyNjIkbzIxNiRnMSR0MTc5NDIxODI5OSRqMjMkbDAkaDA.*_ga_TPGKGE8GTG*czE3OTQyMTgyNjIkbzIxNSRnMSR0MTc5NDIxODI5OSRqMjMkbDAkaDA.\" data-type=\"link\" data-id=\"https:\u002F\u002Fwww.3ds.com\u002Fproducts\u002Fcatia\u002Felectrical-fluid-engineering\u002Felectrical-engineering?_gl=1*wkfgwa*_gcl_au*NzE3ODg1MTU3LjE3OTExOTI3MTM.*_ga*MTI1MDA2OTQzOS4xNzkxMjc5ODc1*_ga_DYJDKXYEZ4*czE3OTQyMTgyNjIkbzIxNiRnMSR0MTc5NDIxODI5OSRqMjMkbDAkaDA.*_ga_TPGKGE8GTG*czE3OTQyMTgyNjIkbzIxNSRnMSR0MTc5NDIxODI5OSRqMjMkbDAkaDA.\">CATIA Electrical Schematic Design\u003C\u002Fa>\u003C\u002Fstrong>, the terminal strip is not a separate drawing you maintain by hand. It is generated directly from the schematic, so it stays consistent with the bill of materials and the wiring data by construction, instead of by discipline. A dedicated editor lets you organise it the way the panel is actually built: terminal order, jumpers, accessories, cable grouping, and how it lays out on the page. When the schematic changes, the strip follows, so the drawing the assembly team relies on is never a version behind.\u003C\u002Fp>\n\n\n\n\u003Cfigure class=\"wp-block-image size-full\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"945\" height=\"474\" src=\"https:\u002F\u002Fblog-assets.3ds.com\u002Fuploads\u002F2026\u002F10\u002Fimage-7.png\" alt=\"\" class=\"wp-image-317066\" srcset=\"https:\u002F\u002Fblog-assets.3ds.com\u002Fuploads\u002F2026\u002F10\u002Fimage-7.png 945w, https:\u002F\u002Fblog-assets.3ds.com\u002Fuploads\u002F2026\u002F10\u002Fimage-7-300x150.png 300w, https:\u002F\u002Fblog-assets.3ds.com\u002Fuploads\u002F2026\u002F10\u002Fimage-7-768x385.png 768w\" sizes=\"auto, (max-width: 945px) 100vw, 945px\" \u002F>\u003C\u002Ffigure>\n\n\n\n\u003Cp>\u003C\u002Fp>\n\n\n\n\u003Ch2 class=\"wp-block-heading\" id=\"distributed-terminals-complexity-without-the-clutter-1\">\u003Cstrong>Distributed terminals: complexity without the clutter\u003C\u002Fstrong>\u003C\u002Fh2>\n\n\n\n\u003Cp>Large junction blocks and grounding terminals used to come with a constraint: every connection point of a circuit had to sit on one single symbol, however many there were. On a block with a dozen or more connections, that meant one crowded, hard-to-read symbol, whether or not the layout made sense for the page. Distributed terminals removes that constraint. Connection points can now be split across several symbols, placed wherever the design reads best, while the software keeps them as one coherent circuit underneath. The terminal strip editor follows the same logic, with a clearer, colour-coded view of every connection so a busy strip stays readable at a glance.\u003C\u002Fp>\n\n\n\n\u003Cfigure class=\"wp-block-image size-full\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"718\" height=\"604\" src=\"https:\u002F\u002Fblog-assets.3ds.com\u002Fuploads\u002F2026\u002F10\u002Fimage-11.png\" alt=\"\" class=\"wp-image-317091\" srcset=\"https:\u002F\u002Fblog-assets.3ds.com\u002Fuploads\u002F2026\u002F10\u002Fimage-11.png 718w, https:\u002F\u002Fblog-assets.3ds.com\u002Fuploads\u002F2026\u002F10\u002Fimage-11-300x252.png 300w\" sizes=\"auto, (max-width: 718px) 100vw, 718px\" \u002F>\u003C\u002Ffigure>\n\n\n\n\u003Ch2 class=\"wp-block-heading\" id=\"-2\"> \u003C\u002Fh2>\n\n\n\n\u003Ch2 class=\"wp-block-heading\" id=\"why-it-matters-panel-by-panel-3\">\u003Cstrong>Why it matters, panel by panel\u003C\u002Fstrong>\u003C\u002Fh2>\n\n\n\n\u003Cp>This concerns anyone who builds or uses control panels. Machine builders shipping packaging, filling, or handling equipment each ship a cabinet with every machine, and a clean terminal strip is what lets their assembly team wire it right the first time. Automation integrators wiring full production cells and lines are managing many panels at once, where consistency across strips is what keeps a project on schedule. Panel and switchgear shops building low-voltage distribution and control boards to order live and die by how fast and how accurately a strip can be wired and checked. Engineering teams in energy, power distribution, water, and process plants deal with long strips and high-consequence mistakes, where a misread terminal is not a minor fix. And the newer wave of energy storage, EV charging, and electrified mobility cabinets brings rising volumes where repeatable, error-proof wiring is what keeps production moving.\u003C\u002Fp>\n\n\n\n\u003Cfigure class=\"wp-block-image size-full\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"945\" height=\"564\" src=\"https:\u002F\u002Fblog-assets.3ds.com\u002Fuploads\u002F2026\u002F10\u002Fimage-10.png\" alt=\"\" class=\"wp-image-317069\" srcset=\"https:\u002F\u002Fblog-assets.3ds.com\u002Fuploads\u002F2026\u002F10\u002Fimage-10.png 945w, https:\u002F\u002Fblog-assets.3ds.com\u002Fuploads\u002F2026\u002F10\u002Fimage-10-300x179.png 300w, https:\u002F\u002Fblog-assets.3ds.com\u002Fuploads\u002F2026\u002F10\u002Fimage-10-768x458.png 768w\" sizes=\"auto, (max-width: 945px) 100vw, 945px\" \u002F>\u003C\u002Ffigure>\n\n\n\n\u003Cp>Across all of them, the same terminal strip, generated right and easy to follow, means fewer wiring errors, faster assembly, and faster troubleshooting when something needs a second look.\u003C\u002Fp>\n\n\n\n\u003Ch2 class=\"wp-block-heading\" id=\"conclusion-4\">\u003Cstrong>Conclusion\u003C\u002Fstrong>\u003C\u002Fh2>\n\n\n\n\u003Cp>The terminal strip is a compact part of a control cabinet, but a critical one: it is where engineering information meets physical assembly. Generating it directly from the schematic keeps it consistent as the design evolves, while the dedicated editor gives a practical way to organize terminals, jumpers, accessories and cable groups.\u003C\u002Fp>\n\n\n\n\u003Cp>Distributed terminals add another layer of flexibility by allowing complex connection points to be spread across multiple symbols while remaining part of the same circuit. Together, these capabilities make terminal information easier to read and easier to use on the shop floor, supporting faster assembly and troubleshooting across a wide range of control-panel applications.\u003C\u002Fp>\n\n\n\n\u003Ch2 class=\"wp-block-heading\" id=\"faq-5\">\u003Cstrong>FAQ\u003C\u002Fstrong>\u003C\u002Fh2>\n\n\n\u003Cdiv class=\"block-faq-items\" itemscope itemtype=\"https:\u002F\u002Fschema.org\u002FFAQPage\">\u003Cdiv id=\"faq-item-1\" class=\"accordion-item\" itemscope itemprop=\"mainEntity\" itemtype=\"https:\u002F\u002Fschema.org\u002FQuestion\">\u003Cdiv class=\"ds-accordion-header\">\u003Ch3 class=\"ds-accordion-subtitle\">\u003Cbutton id=\"faq-item-1-button\" class=\"ds-accordion-button\" aria-expanded=\"false\" aria-controls=\"faq-item-1-content\">\u003Cspan itemprop=\"name\">What is the role of a terminal strip in a control cabinet?\u003C\u002Fspan>\u003C\u002Fbutton>\u003C\u002Fh3>\u003Cdiv class=\"ds-accordion-icon\">\u003Ci class=\"Icon Icon--chevronBottom\">\u003C\u002Fi>\u003C\u002Fdiv>\u003C\u002Fdiv>\u003Cdiv class=\"ds-accordion-content\" aria-labelledby=\"faq-item-1-button\" style=\"max-height: 0; transition: max-height 0.4s ease-in-out, opacity 0.4s ease-in-out; opacity: 0;\" itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\u002F\u002Fschema.org\u002FAnswer\">\u003Cdiv id=\"faq-item-1-content\" class=\"ds-accordion-content-item text-[16px] leading-[24px] legacy-xlg:!text-[18px] legacy-xlg:leading-[28px]\">\u003Cdiv itemprop=\"text\">\u003Cp>The terminal strip provides the connection point between the cabinet&#8217;s internal wiring and external field connections. Because assembly teams rely on it for wiring the panel, clarity and consistency are important.\u003C\u002Fp>\u003C\u002Fdiv>\u003C\u002Fdiv>\u003C\u002Fdiv>\u003C\u002Fdiv>\u003Cdiv id=\"faq-item-2\" class=\"accordion-item\" itemscope itemprop=\"mainEntity\" itemtype=\"https:\u002F\u002Fschema.org\u002FQuestion\">\u003Cdiv class=\"ds-accordion-header\">\u003Ch3 class=\"ds-accordion-subtitle\">\u003Cbutton id=\"faq-item-2-button\" class=\"ds-accordion-button\" aria-expanded=\"false\" aria-controls=\"faq-item-2-content\">\u003Cspan itemprop=\"name\">How is the terminal strip generated in CATIA Electrical?\u003C\u002Fspan>\u003C\u002Fbutton>\u003C\u002Fh3>\u003Cdiv class=\"ds-accordion-icon\">\u003Ci class=\"Icon Icon--chevronBottom\">\u003C\u002Fi>\u003C\u002Fdiv>\u003C\u002Fdiv>\u003Cdiv class=\"ds-accordion-content\" aria-labelledby=\"faq-item-2-button\" style=\"max-height: 0; transition: max-height 0.4s ease-in-out, opacity 0.4s ease-in-out; opacity: 0;\" itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\u002F\u002Fschema.org\u002FAnswer\">\u003Cdiv id=\"faq-item-2-content\" class=\"ds-accordion-content-item text-[16px] leading-[24px] legacy-xlg:!text-[18px] legacy-xlg:leading-[28px]\">\u003Cdiv itemprop=\"text\">\u003Cp>The terminal strip is generated directly from the schematic rather than maintained as a separate drawing. This keeps it consistent with the bill of materials and wiring data, and allows it to follow schematic changes.\u003C\u002Fp>\u003C\u002Fdiv>\u003C\u002Fdiv>\u003C\u002Fdiv>\u003C\u002Fdiv>\u003Cdiv id=\"faq-item-3\" class=\"accordion-item\" itemscope itemprop=\"mainEntity\" itemtype=\"https:\u002F\u002Fschema.org\u002FQuestion\">\u003Cdiv class=\"ds-accordion-header\">\u003Ch3 class=\"ds-accordion-subtitle\">\u003Cbutton id=\"faq-item-3-button\" class=\"ds-accordion-button\" aria-expanded=\"false\" aria-controls=\"faq-item-3-content\">\u003Cspan itemprop=\"name\">What are distributed terminals?\u003C\u002Fspan>\u003C\u002Fbutton>\u003C\u002Fh3>\u003Cdiv class=\"ds-accordion-icon\">\u003Ci class=\"Icon Icon--chevronBottom\">\u003C\u002Fi>\u003C\u002Fdiv>\u003C\u002Fdiv>\u003Cdiv class=\"ds-accordion-content\" aria-labelledby=\"faq-item-3-button\" style=\"max-height: 0; transition: max-height 0.4s ease-in-out, opacity 0.4s ease-in-out; opacity: 0;\" itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\u002F\u002Fschema.org\u002FAnswer\">\u003Cdiv id=\"faq-item-3-content\" class=\"ds-accordion-content-item text-[16px] leading-[24px] legacy-xlg:!text-[18px] legacy-xlg:leading-[28px]\">\u003Cdiv itemprop=\"text\">\u003Cp>Distributed terminals allow connection points belonging to the same circuit to be split across several symbols. The software maintains them as one coherent circuit while allowing the symbols to be positioned where the design is easier to understand.\u003C\u002Fp>\u003C\u002Fdiv>\u003C\u002Fdiv>\u003C\u002Fdiv>\u003C\u002Fdiv>\u003Cdiv id=\"faq-item-4\" class=\"accordion-item\" itemscope itemprop=\"mainEntity\" itemtype=\"https:\u002F\u002Fschema.org\u002FQuestion\">\u003Cdiv class=\"ds-accordion-header\">\u003Ch3 class=\"ds-accordion-subtitle\">\u003Cbutton id=\"faq-item-4-button\" class=\"ds-accordion-button\" aria-expanded=\"false\" aria-controls=\"faq-item-4-content\">\u003Cspan itemprop=\"name\">How can the terminal strip editor help panel builders?\u003C\u002Fspan>\u003C\u002Fbutton>\u003C\u002Fh3>\u003Cdiv class=\"ds-accordion-icon\">\u003Ci class=\"Icon Icon--chevronBottom\">\u003C\u002Fi>\u003C\u002Fdiv>\u003C\u002Fdiv>\u003Cdiv class=\"ds-accordion-content\" aria-labelledby=\"faq-item-4-button\" style=\"max-height: 0; transition: max-height 0.4s ease-in-out, opacity 0.4s ease-in-out; opacity: 0;\" itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\u002F\u002Fschema.org\u002FAnswer\">\u003Cdiv id=\"faq-item-4-content\" class=\"ds-accordion-content-item text-[16px] leading-[24px] legacy-xlg:!text-[18px] legacy-xlg:leading-[28px]\">\u003Cdiv itemprop=\"text\">\u003Cp>The editor lets users organize the terminal order, jumpers, accessories and cable grouping according to how the panel is built. It also provides a clearer view of connections, so complex terminal strips remain easier to read.\u003C\u002Fp>\u003C\u002Fdiv>\u003C\u002Fdiv>\u003C\u002Fdiv>\u003C\u002Fdiv>\u003Cdiv id=\"faq-item-5\" class=\"accordion-item\" itemscope itemprop=\"mainEntity\" itemtype=\"https:\u002F\u002Fschema.org\u002FQuestion\">\u003Cdiv class=\"ds-accordion-header\">\u003Ch3 class=\"ds-accordion-subtitle\">\u003Cbutton id=\"faq-item-5-button\" class=\"ds-accordion-button\" aria-expanded=\"false\" aria-controls=\"faq-item-5-content\">\u003Cspan itemprop=\"name\">Who can benefit from clearer terminal strip management?\u003C\u002Fspan>\u003C\u002Fbutton>\u003C\u002Fh3>\u003Cdiv class=\"ds-accordion-icon\">\u003Ci class=\"Icon Icon--chevronBottom\">\u003C\u002Fi>\u003C\u002Fdiv>\u003C\u002Fdiv>\u003Cdiv class=\"ds-accordion-content\" aria-labelledby=\"faq-item-5-button\" style=\"max-height: 0; transition: max-height 0.4s ease-in-out, opacity 0.4s ease-in-out; opacity: 0;\" itemscope itemprop=\"acceptedAnswer\" itemtype=\"https:\u002F\u002Fschema.org\u002FAnswer\">\u003Cdiv id=\"faq-item-5-content\" class=\"ds-accordion-content-item text-[16px] leading-[24px] legacy-xlg:!text-[18px] legacy-xlg:leading-[28px]\">\u003Cdiv itemprop=\"text\">\u003Cp>The approach applies across control-panel applications, including machine builders, automation integrators, panel and switchgear shops, and engineering teams working in areas such as energy, power distribution, water and process plants. It is also relevant to newer applications such as energy storage, EV charging and electrified mobility.\u003C\u002Fp>\u003C\u002Fdiv>\u003C\u002Fdiv>\u003C\u002Fdiv>\u003C\u002Fdiv>\u003C\u002Fdiv>","2026-11-09T09:59:58",[],{"node":45,"__typename":56},{"nicename":46,"description":47,"slug":48,"name":48,"firstName":49,"lastName":50,"avatar":51,"__typename":55},"imad-soultana","Imad Soultana is a Product Portfolio Manager who shapes the future of 2D electrical design tools. He defines product strategy and roadmap for Electrical Schematic and the Electrical Content Portal, turning customer needs and market trends into new functionalities, and he drives their go-to-market, release communications and cross-team partnerships. He holds a master’s degree in Electric Energy Systems from Université Le Havre Normandie, and his background in electrical design, R&amp;D and embedded systems engineering gives him a practical understanding of the engineers he builds for. Outside of work, he is passionate about soccer, video games and car racing.","Imad Soultana","Imad","Soultana",{"default":52,"url":53,"__typename":54},"mm","https:\u002F\u002Fblog-assets.3ds.com\u002Fuploads\u002F2026\u002F08\u002Fcropped-image-34-96x96.png","Avatar","User","NodeWithAuthorToUserConnectionEdge",{"edges":58,"nodes":71,"__typename":78},[59,66],{"isPrimary":60,"node":61,"__typename":65},true,{"slug":62,"name":63,"__typename":64},"design-simulation","Design & Simulation","Taxonomy_topic","PostToTaxonomy_topicConnectionEdge",{"isPrimary":67,"node":68,"__typename":65},false,{"slug":69,"name":70,"__typename":64},"manufacturing","Manufacturing",[72,75],{"id":73,"name":63,"uri":74,"__typename":64},"dGVybTo4NTU5","\u002Ftopics\u002Fdesign-simulation\u002F",{"id":76,"name":70,"uri":77,"__typename":64},"dGVybTo4MDE0","\u002Ftopics\u002Fmanufacturing\u002F","PostToTaxonomy_topicConnection",{"nodes":80,"__typename":90},[81,86],{"id":82,"name":83,"uri":84,"__typename":85},"dGVybTo4Nzc0","Electromagnetics","\u002Ftags\u002Felectromagnetics\u002F","Taxonomy_tag",{"id":87,"name":88,"uri":89,"__typename":85},"dGVybTo5MTMx","Engineering","\u002Ftags\u002Fengineering\u002F","PostToTaxonomy_tagConnection",{"edges":92,"nodes":99,"__typename":101},[93],{"isPrimary":60,"node":94,"__typename":98},{"slug":95,"name":96,"__typename":97},"catia","CATIA","Taxonomy_brand","PostToTaxonomy_brandConnectionEdge",[100],{"name":96,"slug":95,"__typename":97},"PostToTaxonomy_brandConnection",{"nodes":103,"__typename":107},[104],{"name":105,"__typename":106},"building & infrastructure","Taxonomy_keyword","PostToTaxonomy_keywordConnection",{"title":109,"metaDesc":110,"opengraphAuthor":111,"opengraphDescription":110,"opengraphTitle":20,"opengraphUrl":112,"opengraphSiteName":113,"opengraphPublishedTime":114,"opengraphModifiedTime":115,"twitterTitle":111,"twitterDescription":111,"readingTime":116,"metaRobotsNoindex":117,"__typename":118},"Terminal Strip Design in CATIA Electrical | Fewer Wiring Errors","Terminal strip design in CATIA Electrical: generated from the schematic for fewer wiring errors and faster assembly.","","https:\u002F\u002Fblog-frontoffice-contrib-prd.itvpc.3ds.com\u002Fbrands\u002Fcatia\u002Fterminal-strip-design-catia-electrical\u002F","Dassault Systèmes blog","2026-11-09T09:59:58+00:00","2026-11-09T10:00:02+00:00",5,"index","PostTypeSEO","Post","RootQueryToPostConnection",{},{},1794234346647]